Manufacturing Waste Heat Transfer Products to Save Energy
Waste Heat Recovery Systems
Cost Savings Analysis
Heat Recovery Silencer - Radial (HRSR) x7
Data without a Cain System
- Combustion source: Engine generator
- Heat Sink :Glycol / Water loop
- Waste Exhaust Temp: 922 °F
- Water Temp Inlet:180°F
- SCFM: 2,766
- Fuel Type: Landfill Gas
- O2 Content: N/A
- Excess Air: N/A
- Fuel Cost Per Therm: $0.60
- Annual Operating Hours: 6,000
Performance with a Cain System
- Circulating Liquid Flow : 300 GPM
- Final Exhaust Temp: 387°F
- Water Temp. Outlet: 194.1 °F
- Water Pressure Drop: 0.49 PSIG
- Exhaust Pressure Drop: 0.73 WC"
- BTU/hr Recovered: 1,845,000
- Total Cost: $47,431
- Payback: 6.9 months
- Annual Return On Investment: 175%
- Annual Savings: $83,006